Most whole-house SPDs protect your home with metal oxide varistors, or MOVs. An MOV sits quietly across the power lines at normal voltage, doing nothing at all. When a surge arrives, it clamps in under a nanosecond, shunting the excess voltage to ground and sacrificing a tiny piece of itself in the process. That sacrifice is the whole design: the component absorbs energy so your refrigerator, HVAC controls, and televisions do not have to.
The catch is that the damage is cumulative. The big, dramatic surges from lightning get all the attention, but the slow wear comes from the small ones — motors switching on and off, air-conditioner compressors cycling, and utility switching on the grid. A typical home sees dozens of these small surges a year. Each one erodes the MOVs a little, and there is no way to top them back up.
That is why there is no fixed expiry date printed on the box, only a warranty period. A protector in a lightning-prone area with frequent storms may be heavily worn in 5 years, while the same model on a stable grid with few storms can still be healthy at 10. The honest rule is therefore a range, not a date: plan on 5 to 10 years, check the indicators regularly, and replace on evidence, not on hope.
The first sign is the simplest: the status light is out. Nearly every whole-house SPD has at least one green LED that means protection is present. If it is dark while the panel has power, the protection is gone or the unit has failed. Do not assume a loose bulb or a quirk — treat a dead indicator as a dead protector until an electrician proves otherwise.
The second sign is an audible alarm. Better units, such as the Siemens FS140, beep and flash a red service light when their protection is spent or when they detect a ground-reference problem. If your SPD starts beeping, do not just silence it and move on. The alarm is the device telling you, in the clearest terms it has, that it has done its job and needs replacing.
The third sign is an event, not a symptom: a direct or nearby lightning strike, a major utility fault, or a surge that damaged other equipment in the house. After an event like that, check the SPD immediately. Even if the light is still on, a severe surge can degrade the MOVs enough that the next surge gets through. Many electricians recommend replacing the unit after a confirmed major strike regardless of what the lights say, because the cost of a new SPD is small compared with a second strike hitting unprotected equipment.
The final two signs are age and pattern. If the unit is past 10 years old, replace it on age alone — its MOVs have absorbed a decade of small surges even in a quiet area. And if you start noticing unexplained appliance or electronics failures, flickering control boards, or tripping breakers after storms, a spent SPD belongs on the suspect list. None of these proves the SPD is dead on its own, but together with an old install date they are a strong case for replacement.
Not all SPDs warn you the same way, and that difference matters more than most buyers realise. A unit with a single LED gives you one binary signal. A unit with staged diagnostics tells you whether the problem is a spent protector or a wiring hazard — two very different situations. Here is how the three most common replacement models compare:
| Model | Surge capacity | Warning signals | Product warranty |
|---|---|---|---|
| Siemens FS140 | 140kA per phase | Green LEDs, audible alarm, flashing red service light, ground-reference monitoring | 10 years |
| Eaton CHSPT2ULTRA | 108kA per phase | LED status indication | See manufacturer terms |
| Square D HEPD80 | 80kA per phase | Single green LED | 5 years |
Surge capacity, measured in kiloamps (kA), is not a lifespan rating — it is headroom. A 140kA unit can absorb larger and more numerous surges before its MOVs are spent than an 80kA unit in the same house, which is one reason the FS140 is the usual recommendation for storm-prone areas. But capacity alone does not decide lifespan: installation quality, grounding, and how surge-heavy your local grid is matter just as much.
Warranty length is a useful proxy but not a guarantee. A 10-year warranty means the manufacturer expects the unit to survive that long under normal conditions, not that it will protect you for exactly 10 years and then stop. Treat the warranty as the outside edge of planning, not a promise to ignore the lights until the warranty letter arrives. And keep your receipt and install date: connected-equipment warranty claims, where they exist, usually require proof of purchase and professional installation.
Checking an SPD is a visual job, not a hands-on one. Find the unit — it is usually mounted beside or below your main breaker panel, or wired into it — and look at its indicator lights in normal daylight. Green and steady means protection is present. Dark, red, or flashing means call an electrician. If the unit has an alarm, listen for beeping when you are nearby; a beep that started after a storm is a report, not background noise.
Next, find the install date. Write it on a label on or near the unit if it is not already there, and photograph the label for your records. While you are there, note the model number too — it saves a second trip when you eventually order a replacement. Put a twice-yearly reminder in your calendar, ideally at the start of storm season and again six months later, so the check actually happens.
What you must not do is open the breaker panel cover or touch the SPD's wiring to test it. Panel interiors carry lethal voltage even when individual breakers are off, and there is no meaningful homeowner test for an MOV — a multimeter cannot tell you how much surge life is left. The indicator lights are the test. If they are ambiguous, or if you are unsure what you are looking at, that uncertainty is itself the answer: get a licensed electrician to inspect it. Never remove a panel cover, never poke at SPD wiring, and never assume a quiet unit is a healthy one.
A surge protector is replaced as a whole unit, not repaired. There are no user-serviceable parts inside, and opening one voids any warranty and risks a device that looks fine but protects nothing. Replacement is a job for a licensed electrician: the work is inside or beside the main panel, the main breaker must be switched off, and the electrician must verify the wiring, breaker size, and grounding before the new unit is energised. If you are ever unsure about any mains-electricity work, stop and call a licensed electrician — this is exactly the kind of job where confidence is not a substitute for training.
The good news is that a like-for-like replacement is usually quicker and cheaper than the first installation, because the breaker space, wiring route, and mounting are already there. Expect the device itself to be the main cost, with labour for a straightforward swap typically well below a first-time install. If your old unit was undersized for your area — a small 25kA or 50kA unit in a lightning-heavy region, for example — a replacement visit is the right moment to step up to an 80kA or 140kA model rather than repeating the same choice.
When choosing the replacement, match three things: your panel brand and breaker type, the SPD type your installation requires (Type 1 units can sit ahead of the main disconnect; Type 2 units connect through a dedicated breaker), and the surge capacity your area justifies. A universal-fit unit such as the Eaton CHSPT2ULTRA or Square D HEPD80 suits most panels, while the Siemens FS140 is the pick when you want the clearest end-of-life warning — its alarm and ground-reference monitoring remove the guesswork that makes silent failure so risky.
Layered protection is the single best way to extend an SPD's life. A whole-house unit at the panel handles the big external surges; quality point-of-use surge strips at expensive electronics handle the smaller residual surges that get through. Splitting the work means the panel unit absorbs fewer events, and your most sensitive gear gets a second line of defence. It is the same logic as our earlier guides on choosing and installing whole-house protection: one layer is good, two layers are far better.
Grounding matters too. An SPD can only shunt surge energy somewhere safe if the home's grounding and bonding are sound. If your electrician is already on site for a replacement, ask them to check the grounding electrode connections and the neutral-to-ground bond — a compromised bond is both a safety hazard and a reason SPDs die young, and some premium units will actually warn you about it.
Finally, build two cheap habits. First, unplug the most valuable electronics during a severe storm if you can do so safely before it arrives — no protector is a substitute for physical disconnection during a direct strike. Second, re-check the SPD after any major storm, outage, or utility work on your street. A two-minute look at the lights after an event is what turns a 5-to-10-year guess into a device you can actually trust.
Typically 5 to 10 years. The MOVs inside wear out a little with every surge they absorb, so lifespan depends on how surge-heavy your area is: lightning-prone homes may wear one out in 5 years, while a stable grid can stretch one past 10. Replace on evidence — a dead indicator light, an alarm, or a major surge event — and on age alone once it passes about 10 years.
Check its indicator lights: a steady green LED on most units means protection is present, while a dark, red, or flashing light means it has failed or is spent. Some units, like the Siemens FS140, also sound an audible alarm and flash a red service light at end of life. There is no homeowner test beyond the indicators — a multimeter cannot measure remaining surge life — so if the lights are unclear, have an electrician inspect it.
It can. A severe surge, such as a nearby lightning strike, can exhaust the MOVs in a single event even if the unit still looks intact. That is why you should check the indicator lights immediately after any major strike or surge that damaged other equipment, and why many electricians recommend replacing the unit after a confirmed major strike regardless of the lights.
You replace the whole unit. There are no user-serviceable parts inside an SPD, and opening one voids the warranty. Replacement is a job for a licensed electrician, since the work involves the main panel: the main breaker is switched off, the old unit is removed, and the new unit's wiring, breaker size, and grounding are verified before it is energised.
Yes — this is licensed-electrician work. The SPD connects inside or beside the main breaker panel, where lethal voltage is present even with individual breakers off. A straightforward like-for-like replacement is usually quicker than the original installation, since the breaker space and wiring route already exist, but panel work should never be a DIY job.